Casa > QM, Accreditamento, EQAS > Analisi della fluorescenza a raggi X EQAS > 168-2019-geopt44a-cm-1
Logo

Round robin test di analisi XRF XRF EQAS GeoPT 44, Inghilterra - ShCx-1, Scisto calcareo

Organizzatore del round robin test:
Newsletter International Association of Geoanalysts and Geostandards - GeoPT44
Materiale di confronto interlaboratorio:
SHCx-1, Scisto calcareo
Studio completato:
2019 - 1
Letteratura:
Rapporto - GeoPT44 Proficiency Testing Round 44 (codice laboratorio CRB = C85)

Elementi principali [%]

CRBRV1sRVZ-Score
MgO0,5600,4900,0113,210
Al₂O₃1,6401,5600,0291,460
SiO₂7,7707,8300,115-0,240
P₂O50,0680,0610,0022,030
K₂O0,4700,4600,0100,480
CaO48,10047,6000,5320,470
TiO₂0,0860,0800,0021,280
Fe₂O₃tot0,9500,9550,020-0,140
MnO0,0270,0230,0012,460
L.O.I. *39,93040,1200,460-0,210
TC *12,40012,4000,1700,000
CO₂*37,20037,2000,4320,000

Elementi in traccia [µg/g]

CRBRV1sRVZ-Score
Sr298,00290,009,900,42
V75,0060,002,602,89
Zn187,00193,007,00-0,43

leggenda

CRB
Risultati CRB
Prove inter­labora­torio
Risultati studio collaborativo
1s-RV
studio collaborativo sulla deviazione standard
Z-Score
Diferencia entre el valor medido y el estudio promedio
*
Valore non certificato

Analisi dell'amianto0

Analisi affidabile dell'amianto mediante microscopia elettronica a scansione, SEM/EDXORDINA SUBITO!

Sono a disposizione per una consulenza!

  • Tel.: +49 (0)5505 // 940 98-0
  • Fax: +49 (0)5505 // 940 98-260

Notizia

29/nov/2022

Follow-up report: 31st Forum Asbestos and other Building Pollutants

For the 31st time, the Forum Asbestos took place at the Haus der Technik in Essen on November 10th and 11th, 2022. In order to do justice to the continuing situation, this year there was the possibility to participate in person on site, as well as to join online. Here is a summary of our impressions of the conference: Per saperne di più

13/ott/2022

New vdu trainings until the end of 2022

By the end of 2022, the Association of German Testing Laboratories (vdu) would like to hold training at the vdu office in Hannover. As a member of the vdu, we are pleased to point out this interesting opportunity.  Per saperne di più

16/set/2022

La pulizia non corretta dei tetti in amianto porta a pene detentive e pecuniarie

È necessaria una particolare cautela quando si ha a che fare con l'amianto. La polvere di amianto può essere rilasciata non solo durante i lavori di ristrutturazione, ma anche quando le coperture in amianto vengono pulite in modo improprio. Chi non rispetta le norme mette in pericolo se stesso e i suoi simili e rischia pesanti sanzioni. Per saperne di più