Casa > QM, Accreditamento, EQAS > Analisi della fluorescenza a raggi X EQAS > 033-2002-st-gobain-sgid
Logo

Round robin tests XRF-analysis XRF EQAS St Gobain - SGID, vetro borosilicato

Organizzatore del round robin test:
Isover San Gobain - CRIR
Materiale di confronto interlaboratorio:
SGID, vetro borosilicato
Study finished:
2002 - 6
Letteratura:
Relazione finale

major elements [wt %]

CRBRV1sRVZ-Score
Na₂O14,82014,7500,160---
MgO2,5302,6300,070---
Al₂O₃3,3403,3000,090---
SiO₂63,58063,4800,360---
P₂O50,1900,0200,012---
SO₃0,1700,1700,030---
K₂O1,8301,8700,070---
CaO7,7707,6800,110---
TiO₂0,6900,0700,013---
Fe₂O₃ tot0,2100,2300,020---
MnO0,5100,5000,031---  

trace elements [µg/g]

CRBRV1sRVZ-Score
Ba1020,00---------  
Cr140,00---------
Rb100,00---------
Sr180,00---------
Zr20,00---------

Legend

CRB
results CRB
cooperative test
results collaborative study
1s-RV
standard deviation collaborative study
Z-Score
Difference of measured value from mean study
*
Value not certified

Analisi dell'amianto0

Analisi affidabile dell'amianto mediante microscopia elettronica a scansione, REM/EDXORDINA SUBITO!

Sono a disposizione per una consulenza!

  • Telefono: +49 (0)5505 // 940 98-0
  • Fax: +49 (0)5505 // 940 98-260

News

23/mar/2020

INTERSCHUTZ si trasferisce nel 2021

La fiera leader nel settore degli incendi, dei soccorsi, della protezione civile e della sicurezza sarà rinviata da giugno di quest'anno a giugno 2021 a causa dell'attuale situazione pandemica. Per saperne di più

19/mar/2020

Ancora in servizio nonostante Corona

Nonostante la situazione critica, siamo ancora pienamente operativi grazie a misure interne mirate. Per saperne di più

12/mar/2020

IFAT 2020 a Monaco di Baviera rinviato a settembre

A causa della continua diffusione del nuovo coronavirus, IFAT 2020, che in realtà è previsto dal 4 all'8 maggio, sarà purtroppo rinviato. Per saperne di più

';