Report - GeoPT47A Proficiency Testing Round 47A(Laborcode CRB = J88)

major elements [wt %]

CRBRV1sRVZ-Score
SiO₂80,12080,1500,829-0,020
TiO₂0,6960,7000,015-0,140
Al₂O₃5,6805,6700,0870,060
Fe₂O₃tot3,1603,1210,0530,370
MnO0,0940,0910,0030,560
MgO0,5000,5000,011-0,060
CaO0,3400,3200,0081,320
Na₂O*0,2800,2820,056-0,020
K₂O1,0401,0450,021-0,120
P₂O50,2270,2300,010-0,260
L.O.I.7,6907,6400,1130,220
TOC*2,6902,5100,4420,200
C-gesamt*2,8202,9300,369-0,150

trace elements [µg/g]

CRBRV1sRVZ-Score
Ba150,00160,506,00-0,88
Cr76,0062,202,702,58
Cu19,0018,000,900,54
Ga10,008,100,502,05
Hf8,508,100,500,42
Nb11,0014,400,80-2,23
Ni21,0019,101,001,00
Pb38,0040,001,80-0,55
Rb48,0054,002,40-1,27
Sr30,0027,001,301,14
V49,0051,002,30-0,44
Y19,0017,800,900,65
Zn68,0064,102,700,71
Zr330,00322,0010,800,37

Legend

CRB
results CRB
cooperative test
results collaborative study
1s-RV
Standard deviation collaborative study
Z-Score
Difference of measured value from mean study
*
Value not certified

Asbestos Analysis0

Reliable analysis of asbestos with SEM/EDXORDER NOW!

Order inquiry & contact

  • Tel.: +49 (0)5505 // 940 98-0
  • fax: +49 (0)5505 // 940 98-260

News

Nov 29, 2022

Follow-up report: 31st Forum Asbestos and other Building Pollutants

For the 31st time, the Forum Asbestos took place at the Haus der Technik in Essen on November 10th and 11th, 2022. In order to do justice to the continuing situation, this year there was the possibility to participate in person on site, as well as to join online. Here is a summary of our impressions of the conference: ... read more

Oct 13, 2022

New vdu trainings until the end of 2022

By the end of 2022, the Association of German Testing Laboratories (vdu) would like to hold training at the vdu office in Hannover. As a member of the vdu, we are pleased to point out this interesting opportunity.  ... read more

Sep 16, 2022

Incorrect asbestos roof cleaning leads to imprisonment and fines

Special care is required when handling asbestos. Asbestos dust can be released not only during renovation work but also when asbestos roofs are improperly cleaned. Those who disregard the regulations endanger themselves and their fellow human beings and risk heavy fines. ... read more