Round robin tests XRF-analysis XRF Round-robin test DBW Fiber Neuhaus - Burnt lime
Study organized by:
                    DBW Fiber Neuhaus GmbH
                    
                    Material of proficiency test:
                    Burnt lime
                    
                    Study finished:
                    2011 - 8
                    
                    Literature:
                    Bericht Laborvergleich
                major elements [wt %]
| CRB | RV | 1sRV | Z-Score | ||
| Na₂O* | <0,030 | 0,010 | --- | --- | |
| MgO | 0,830 | 0,800 | 0,050 | --- | |
| Al₂O₃ | 0,200 | 0,230 | 0,050 | --- | |
| SiO₂ | 0,560 | 0,730 | 0,200 | --- | |
| K₂O | 0,014 | 0,018 | 0,004 | --- | |
| CaO | 96,990 | 97,070 | 0,090 | --- | |
| TiO₂ | 0,026 | 0,017 | 0,008 | --- | |
| Fe₂O₃ tot | 0,016 | 0,014 | 0,020 | --- | |
| SO₃ | 0,340 | 0,320 | 0,015 | --- | |
| L.O.I.* | 0,700 | 0,650 | 0,130 | --- | 
trace elements [µg/g]
| CRB | RV | 1sRV | Z-Score | |
Legend
CRB
                            results CRB
                            cooperative test 
                            results collaborative study
                            1s-RV
                            Standard deviation collaborative study
                            Z-Score
                            Difference of measured value from mean study
                            *
                            Value not certified