Home > QM, accreditation, proficiency tests > Round robin tests XRF-analysis > 060-2010-geopt-27-mgl
Logo

Round robin tests XRF-analysis XRF Round-robin test GeoPT27, England - MGL-AND, Andesite

Study organized by:
International Association of Geoanalysts and Geostandards Newsletter - GeoPT27
Material of proficiency test:
MGL-AND, (Andesite)
Study finished:
2010 - 8
Literature:
Preliminary Report - GeoPT27 Proficiency Testing Round

major elements [wt %]

CRBRV1sRVZ-Score
Na₂O4,4104,4800,071
MgO3,5603,5500,059
Al₂O₃16,78016,6900,219
SiO₂59,27059,2300,641
P₂O50,2620,2610,006
K₂O2,3702,4000,042
CaO5,5505,5800,086
TiO₂0,7170,7140,015
Fe₂O₃ tot.5,5505,4200,084
MnO0,0800,0800,002
L.O.I.*1,3001,4000,030

trace elements [µg/g]

CRBRV1sRVZ-Score
As2,402,700,20
Ba680,00673,0020,00
Ce50,0053,002,30
Co25,0019,501,00
Cr101,0095,003,80
Cu34,0041,301,90
Ga20,0021,001,10
Hf3,403,600,20
La25,0025,401,20
Nb1,003,400,20
Nd29,0026,301,30
Ni62,0062,502,70
Pb10,0018,300,90
Pr4,006,500,40
Rb33,0049,902,20
Sm3,005,100,30
Sr1125,001116,0031,10
Th7,006,200,40
U1,001,900,10
V115,00121,004,70
Y11,0012,000,10
Zn71,0070,003,00
Zr126,00148,005,60

Legend

CRB
results CRB
cooperative test
results collaborative study
1s-RV
standard deviation collaborative study
Z-Score
Difference of measured value from mean study
*
Value not certified

Asbestos Analysis0

Reliable analysis of asbestos with SEM/EDXORDER NOW!

Order inquiry & contact

  • Phone: +49 (0)5505 // 940 98-0
  • fax: +49 (0)5505 // 940 98-260

News

Mar 4, 2019

Test method developed for asbestos decontamination of firefighters' clothing

In fire situations, firefighters are exposed to a variety of hazardous substances, including asbestos. In cooperation with the MeyerundKuhl specialist laundry, CRB has developed a test procedure to check whether fire-fighting textiles can be sufficiently decontaminated by washing and impregnation. ... read more

Feb 28, 2019

We say goodbye to the old SEM XL 40

After 9 years of use in the field of asbestos analysis we say goodbye to our old SEM XL 40 and plan to purchase two new Thermo Scientific Prisma E scanning electron microscopes to replace it. ... read more

Feb 20, 2019

Review of the DCONex 2019: Building pollutants & construction in existing buildings

We report on our impressions of DCONex 2019, which took place on 30 and 31 January in Essen. For the first time we were represented at the fair with our own stand. ... read more